TECK90 – Copper Conductor

Northern Cables Teck90Northern Cables Inc.’s TECK90 is an interlocked armoured cable for use in petro-chemical, pulp and paper, and other industrial application environments. TECK90 can be used in open and concealed wiring, direct burial, and in hazardous locations.

The insulated conductors are made with cross-linked polyethylene and twisted with an uninsulated ground wire. The twisted core is covered with a PVC jacket, then covered with either interlocked aluminum or galvanized steel, and covered with a PVC jacket over the armour.

TECK90 is manufactured to CSA C22.2#131 and CSA C22.2 #174 to allow it to meet the certain CSA tests including; flame test FT4,-40C cold temperature impact test, low acid gas and sunlight resistance.

TECK90 is available in 600 and 1000-volt constructions from #14 to 750 kcmil. Cables can be manufactured up to 50 conductors. Custom cables are available upon request including composites, vertical riser, and coloured jackets.

Designations

  • CSA C22.2 No. 131
  • FT4
  • -40 C to +90 C
  • HL
  • AG14
  • Sunlight Resistance
  • Direct Burial

Conductor:
14 AWG. round concentric lay class “B” stranded copper

Insulation:
Cross-linked Polyethylene (XLPE) Type RW90

Colour Coding:
2 Conductor: black, white
3 Conductor: black, red, blue
4 Conductor: black, red, blue, white
5 – 50 Conductor: black with printed number code

Bonding Conductor (Ground):
One (1) bare stranded class “B” copper conductor

Inner jacket:
Polyvinyl Chloride (PVC), black

Armour:
Aluminum interlocked armour

Outer Jacket:
Low acid gas, flame-retardant, moisture and
sunlight resistant Polyvinyl Chloride (PVC), black

Print:
NORTHERN CABLES™ #/C SIZE (AWG OR KCMIL) TECK90 XLPE 600V HL FT4 (-40C) SUN RES AG14 CSA, METRE MARK
CSA Licence:
LL109933

Applications:

  • For concealed wiring in dry or wet locations
  • For exposed wiring in dry or wet locations
  • For exposed and wiring in dry, locations where subjected to corrosive action if suitable for corrosive conditions encountered
  • For exposed wiring where subjected to the weather
  • For use in ventilated, Non-ventilated and ladder-type cable trays in dry or wet locations
  • For direct earth burial (with protection as required by inspection authority)
  • For service entrance above or below ground

Features:

  • Rated at 90°C wet or dry
  • Excellent crush resistance
  • Provides long service life
  • Cost effective alternative to installations in conduit
  • Meets cold bend and impact tests at (-40°C)

Industry compliances: CSA Standard C22.2 No. 131, No.38 and No.2256, RoHS
Flame test compliances: CSA FT4
Hazardous Location, SUN RES (outer jacket) SUN RES on inner jacket and insulated conductor available upon request, Direct Burial
Acid Gas: CSA AG14

Northern Cables logowww.northerncables.com
usasales@northerncables.com
1.888.524.5050

Share on Socials!

Related Articles

Related Articles

TASCO INC. INTRODUCES VOLTAGE SENSING SCREWDRIVER

The HOTROD™ Safety Screwdriver has a transparent handle that flashes red if the blade contacts a live line or if voltage is detected in the proximity ...
Read More

Featured Product from the November 2016 Issue

EZ Spot UR Pole Jack Attachment The EZ Spot UR Pole Jack makes it safe and easy to pull transmission poles up to 100 feet in ...
Read More

Compact Dual Capstan Puller

Cannon 10K Faster 4 Speed dual capstan 9′ & 18′ (per min.) on low speed, 20′ & 40′ on high speed Self contained – ready to ...
Read More

Follow ESW!

Join Our Mailing List

Join Our Mailing List